Test Code C4 Complement C4, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Secondary ID
800020Useful For
Investigating an undetectable total complement
Confirming hereditary angioedema (with low C1 inhibitor)
Assessing disease activity in systemic lupus erythematosus, proliferative glomerulonephritis, rheumatoid arthritis, and autoimmune hemolytic anemia
Method Name
Nephelometry
Reporting Name
Complement C4, SSpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Refrigerated (preferred) | 7 days |
Frozen | 28 days | |
Ambient | 72 hours |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | Reject |
Gross icterus | OK |
Reference Values
14-40 mg/dL
Performing Laboratory

Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86160
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
C4 | Complement C4, S | 4498-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
C4 | Complement C4, S | 4498-2 |
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.
Day(s) Performed
Monday through Friday, Sunday